Badge time.png   The Paragon Wiki Archive documents the state of City of Heroes/Villains as it existed on December 1, 2012.

Difference between revisions of "Invention Origin Enhancement Scaling"

From Paragon Wiki Archive
Jump to: navigation, search
m (Robot: Removing template: Issue9)
m (Added note about graph in lieu of new upload (see forums for issue()
Line 1: Line 1:
 
  
 
For the [[Invention Origin Enhancement]]s that come from rare sets, bonuses are calculated by multiplying the number from the table below, based on the enhancement level and the schedule of the effected aspect, with the multiplier for the number of aspects in the enhancements.  Common Invention Origin Enhancement that come from recipes urchasable from  [[Invention Worktables]] use a slightly different scale.
 
For the [[Invention Origin Enhancement]]s that come from rare sets, bonuses are calculated by multiplying the number from the table below, based on the enhancement level and the schedule of the effected aspect, with the multiplier for the number of aspects in the enhancements.  Common Invention Origin Enhancement that come from recipes urchasable from  [[Invention Worktables]] use a slightly different scale.
Line 18: Line 17:
  
 
[[Image:IO Scaling2.JPG]]
 
[[Image:IO Scaling2.JPG]]
 +
 +
'''Special Note'''
 +
''Since this graph was created the commons IO amiunts have chnaged. Due to the relocation a new graph cannot be added right now. A common IO provides the same boost as the black line - equal to a set based, the new Graph will be uploaded once the permissions issue has been resolved''
 +
  
 
--------------------------------------------------------------------------------
 
--------------------------------------------------------------------------------

Revision as of 12:00, 4 May 2007

For the Invention Origin Enhancements that come from rare sets, bonuses are calculated by multiplying the number from the table below, based on the enhancement level and the schedule of the effected aspect, with the multiplier for the number of aspects in the enhancements. Common Invention Origin Enhancement that come from recipes urchasable from Invention Worktables use a slightly different scale.

# of Aspects Multiplier
1 1
2 0.625
3 0.5
4 0.4375

IO Scaling2.JPG

Special Note Since this graph was created the commons IO amiunts have chnaged. Due to the relocation a new graph cannot be added right now. A common IO provides the same boost as the black line - equal to a set based, the new Graph will be uploaded once the permissions issue has been resolved



Level Schedule A Schedule B Schedule C Schedule D
10 0.117 0.07 0.14 0.21
11 0.133 0.08 0.16 0.24
12 0.15 0.09 0.18 0.27
13 0.167 0.1 0.2 0.3
14 0.179 0.108 0.215 0.323
15 0.192 0.115 0.231 0.346
16 0.205 0.123 0.246 0.369
17 0.218 0.131 0.262 0.392
18 0.231 0.138 0.277 0.415
19 0.243 0.146 0.292 0.438
20 0.256 0.154 0.308 0.462
21 0.269 0.162 0.323 0.485
22 0.282 0.169 0.338 0.508
23 0.295 0.177 0.354 0.531
24 0.307 0.185 0.369 0.554
25 0.32 0.192 0.385 0.577
26 0.333 0.2 0.4 0.6
27 0.337 0.202 0.405 0.607
28 0.341 0.205 0.409 0.614
29 0.344 0.207 0.414 0.62
30 0.348 0.209 0.418 0.627
31 0.352 0.211 0.423 0.634
32 0.356 0.214 0.427 0.641
33 0.359 0.216 0.432 0.648
34 0.363 0.218 0.436 0.655
35 0.367 0.22 0.441 0.661
36 0.371 0.223 0.445 0.668
37 0.375 0.225 0.45 0.675
38 0.378 0.227 0.455 0.682
39 0.382 0.23 0.459 0.689
40 0.386 0.232 0.464 0.695
41 0.39 0.234 0.468 0.702
42 0.394 0.236 0.473 0.709
43 0.397 0.239 0.477 0.716
44 0.401 0.241 0.482 0.723
45 0.405 0.243 0.486 0.73
46 0.409 0.245 0.491 0.736
47 0.412 0.248 0.495 0.743
48 0.416 0.25 0.5 0.75
49 0.42 0.252 0.505 0.757
50 0.424 0.255 0.509 0.764
51 0.424 0.255 0.509 0.764
52 0.424 0.255 0.509 0.764
53 0.424 0.255 0.509 0.764